Deck d'Ober

Panel compuesto por lamas de madera macizas juntadas tipo "puente de barco". Destinado al revestimiento de suelos y paredes de cuartos de baño, duchas, piscinas, vestidores y habitaciones.

Ficha producto


Características

LAMAS
ANCHO 41 mm
Especie: Teca maciza (por encargo: wengé, bubinga, doussie macizo)
Largos estándar:
1.200 mm – 2.000 mm
(por encargo: 2.200 mm – 2.500 mm)
Largeurs standards :
639 mm – 1283 mm
voir palette échantillons
LAMAS
ANCHO 87 mm

Especie: Wengé, Bubinga, Doussie macizo
Largos estándar: 2.000 mm
(largo inferior a 2.000 mm, consúltenos)
Anchos estándar: 639 mm – 1283 mm
ver paleta de muestras

ESTADO DE SUPERFICIE Producto entregado en bruto, para aceitar
GROSOR
DE UNA LAMA
7,5 mm
TIPO DE JUNTA Cola masilla elastómero
ANCHO DE LA JUNTA 5 mm


Los paneles DECK De OBER comienzan con una lama de madera y terminan con otra.

Les paneles Deck d' Ober con lamas de 41 mm de ancho pueden utilizarse para la realización de partes curvas:
panel de bañera redondeado, revestimiento de columnas, etc., (radio de curvado: 400 mm)
Para las utilizaciones en exterior o en medio muy húmedo, recomendamos utilizar exclusivamente Teca.

Descargue aquí la documentación Deck D'Ober

Descargue la documentación para la instalación del producto Deck D'ober

Aplicación

Donwload the guide "Advice for laying and maintenance"

The panels should be fabricated in compliance with Specification NF XP B 54-202 : «Panneaux décoratifs plaqués-bois – Spécifications (Decorative, wood-veneered panels - Specification) or equivalent.

On-site fabrication conditions

Fabrication should normally take place in the following conditions:

• Prior to installation, the panels must be stabilized to ambient conditions. To this effect, store them for at least 3 days in a flat position in the place where they are eventually to be installed.

• When installing the panels, allow for a 1 mm/m expansion joint.

• Increase that joint to 1.5 mm/m in the following cases :

- for rooms likely to be subjected to major atmospheric

- humidity variations

- in cases where flame-retardent (M1-rated) panels are used.

On-site conditions

The rooms where the panels are to be installed should normally conform to the following conditions:

• they should be roofed

• they must have been heated or air-conditioned for at least 24 hours

• all cement and plasterworks should be dry

• ambient temperature must not fall to below 15° C

• ambient air humidity during the stabilization process and at the time of installation should respond to the following criteria

If the panels are installed in a dry area: The relative air humidity during the stablilization phase should be within the range of 40 to 60%. Once the panels are installed, the ambient air humidity may exceed 65% only for a couple of weeks per annum.

If the panels are installed in a humid area (bonded to a hydrophobic substrate):

The relative air humidity during the stabilization phase may exceed the range of 40 to 60%.