Obersound, collections 5.5 designers
CHARACTERISTICS
| JOINTING | Bookmatched or random-matched (depends on the references) |
| FINISHES |
Relief • satin • matte • brshed (depends on the references) |
| SUBSTRATES | MDF (black or brown, depends on the references) others: please contact us |
| SUBSTRATE THICKNESS | 16 mm |
| DIMENSIONS |
249 x 120 cm • 249 x 60 cm • 249 x 40 cm others: please contact us |
| COUNTERBALANCING | A/C : 1 visible side • 1 counterbalancing side |
| PERFORATIONS |
25 models of holes grouped in 5 collections (see collections) |
| EDGE FINISH | Veneered (with the Oberflex edge banding) • unfinished• others: please contact us See Edge banding |
| EDGE TREATMENT | Precision-milled • custom traited : grooved, rebated, angle machining |
| FIRE RATINGS | Upon request : M1 (n° 9152-00 du SNPE) Bs1d0 (PV N°09AN0343) |
Download technical details for Obersound, collections 5.5 designers
The panels should be fabricated in compliance with Specification NF XP B 54-202 : «Panneaux décoratifs plaqués-bois – Spécifications (Decorative, wood-veneered panels - Specification) or equivalent.
On-site fabrication conditions
Fabrication should normally take place in the following conditions:
- Prior to installation, the panels must be stabilized to ambient conditions. To this effect, store them for at least 3 days in a flat position in the place where they are eventually to be installed.
- When installing the panels, allow for a 1 mm/m expansion joint.
- Increase that joint to 1.5 mm/m in the following cases :
- for rooms likely to be subjected to major atmospheric
- humidity variations
- in cases where flame-retardent (M1-rated) panels are used.
On-site conditions
The rooms where the panels are to be installed should normally conform to the following conditions:
- they should be roofed
- they must have been heated or air-conditioned for at least 24 hours
- all cement and plasterworks should be dry
- ambient temperature must not fall to below 15° C
- ambient air humidity during the stabilization process and at the time of installation should respond to the following criteria
If the panels are installed in a dry area: The relative air humidity during the stablilization phase should be within the range of 40 to 60%. Once the panels are installed, the ambient air humidity may exceed 65% only for a couple of weeks per annum.
If the panels are installed in a humid area (bonded to a hydrophobic substrate):
The relative air humidity during the stabilization phase may exceed the range of 40 to 60%.
Once the panels are installed, the ambient air humidity may exceed 85% only for a couple of weeks per annum.